Call Us Now! +6017-531 6513        Fax: +603-5887 3674

Recent Updates

CSE Advance (SEL) Sdn Bhd added 2 new photos in EXPLOSION PROOF LIGHT
Mar 1, 2023 at 04:18 pm —
Mining Light Explosion Proof Light HDA Series
MV01 Remote Area Lighting System
CSE Advance (SEL) Sdn Bhd added 3 new photos
Mar 1, 2023 at 04:14 pm —
Mining Light WKE Series Explosion-proof Rechargeable LED Hand Lamp
ES01 LED Explosion Proof Exit Light
Explosion Proof CPA Series - Oil Station Light
CSE Advance (SEL) Sdn Bhd added 6 new photos in EXPLOSION PROOF LIGHT
Mar 1, 2023 at 11:11 am —
CSE Advance (SEL) Sdn Bhd added new photo in Ventilating Valve/ Air Release Valve
Mar 31, 2021 at 12:16 pm —
VENTILATING VALVE/AIR RELEASE VALVE

VENTILATING VALVE/AIR RELEASE VALVE

Feature: Prime,High Quality Standards:NPT,BSP,ISO,DIN Material:ss304,316,316L Certificates:ISO9001:2008, CE Brand Name: FD-LOK Details: Pressure up to 6000 psig (414 bar) for standard series Temperature from -65¡ãF to 450¡ãF ( -54¡ãC to 232¡ãC )with PTFE packing Safe union-bonnet constrution Back seating design protects the packing in fully open position Panel mountable Packing below stem thread isolates the thread lubricants from the media Non-rotating stem tip 100% factory tested read more
CSE Advance (SEL) Sdn Bhd added new service in WATER SURGE
Nov 30, 2020 at 08:39 am —

WANDA SURGE ANALYSIS

CONTENTS   1.0 INTRODUCTION 2.0 SURGE ANALYSIS 2.1 Assumptions 3.0 SYSTEM MODELLING 3.1 WANDA Deltares System 4.0 TRANSIENT ANALYSIS A) Engineering / Steady State B) Transient State C) Control Module / State 5.0 SURGE SUPPRESSION EQUIPMENT 5.1 Surge Control in Water Distribution System 6.0 CONCLUSION 1.0 INTRODUCTION   Pipeline pressure surges are occurred by a sudden increase in pressure which is produced by a change in velocity of the moving fluid in a pipeline. Usually, during pipeline design, the movement of fluid is based on steady state calculations of the static head and frictional head losses, using the maximum operating pressure plus a small safety factor. However, in any system, the flow must be started and stopped by pump or valve operations and these can generate transient pressures well in excess of the steady state pressures. The hydraulic simulation of pressure and flows in fluids caused by the transient operations of the pumps and valves are required to carryout for the pipeline surge analysis studies. The pressure surges occur due to the events such as shutting down of a pumping station or pumping unit, unstable controls, oscillation in tank levels, the sudden closure of a valve, or any other sudden blockage of the moving fluid. These pressure surges may occur in all fluid pipeline systems and can result in pipeline fatigue and pipeline failure. The effects of surge may be catastrophic failure of the pipeline system and equipment or fatigue failure of the pipeline supports, instrumentation, equipment and compounds. Therefore, a thorough understanding of the hydraulic behaviour in a pipeline system is essential to guarantee a low cost, safe and reliable system. However, it will need sort of experiences to get such thorough understanding of this behaviour in the system, especially the dynamic behaviour,because it is often considered a complex task.  As transient conditions can result in many situations, engineers are naturally are more concerned with those that might endanger the safety of a plant and its personnel, have the potential to cause equipment or device damage, or result in operational difficulties. Hence, the severity of transient pressure must be determined by using a system or device that can prevent hydraulic water hammer effect. 2.0 SURGE ANALYSIS   Introducing a developing water hammer software, WANDA, by Deltares , used to assist hydraulic engineers in the hydraulic analysis of pipeline systems. By using software program WANDA, we aim to simplify the complex task of assessing pipeline system throughout the entire life cycle so that user can get a thorough understanding of their pipeline system with just a few clicks.   2.1 ASSUMPTIONS   i. One dimensional flow. ii. A common pressure at pipeline section. iii. An average velocity at each pipe section. iv. The pipe is full and remain full during the transient. v. The pipe wall and fluid behave linear elastically. vi. Pipe: Modulus of elasticity of Steel :200 GPa Poisson ratio : 0.27 Conduit condition :Thin wall and elastic Friction factor : C100 vii. Fluid: Media :Water Bulk modulus :2.19 GPa Density :1000 kg/m3 Operating temperature :Ambient 3.0 SYSTEM MODELLING   WANDA consists of 2 calculation modes (Engineering and Transient) and 4 modules (Liquid, Heat, Multi-species transport and Control). The modes are integrated in the core of WANDA, together with the system control functionality. The modules are connected to the core upon request of the user when the software is purchased. Each mode contains a component library specific for that domain. The user can then access the modes and modules through the user interface.      Figure 1: The architecture of WANDA 4   3.1 WANDA Deltares System   WANDA is a powerful and user-friendly program for the hydraulic design and optimization of pipeline system. Both engineers and operators use WANDA to study the steady state and dynamic behavior of liquid, heat, gas and slurry flows in arbitrarily configured pipeline networks.   The software can be easily linked to other applications, for example operator training systems or advanced real-time control. WANDA has been extensively tested, validated and designed for engineers by engineers.It can be used throughout the lifetime of the pipeline system; from initial design, component optimization, control procedure evaluation up to commissioning and operator training. In fact, detailed information of the flow can be viewed at any location in the system at any moment in time.   Special features:   • Intuitive look and feel based on iGrafx Flowcharter® • Copy/paste of components, diagrams, graphs, tabular results and input parameters • Different layers for text and background • connector-tool to separate details or subsystems from the main model • input and output properties in spreadsheet view • Comparison of complete cases with case-compare • Animation function to analyse wave propagation and reflection • Several unit systems (standard SI, US, UK, user defined) are supported 4.0 TRANSIENT ANALYSIS   A) Engineering /Steady State The Engineering mode is used for steady state analysis of the pipeline system. This mode allows user to perform common activities in the hydraulic design of the pipeline system, such as pipe sizing and capacity analysis. In this mode, the performance of the pipeline system can be quickly analyzed and optimized through continuous parameter changes and reruns. This mode assists you with: • Head loss calculations • Pipe, pump & valve sizing • Flow capacity analysis • Hydraulic gradient & pressure analysis • Pump & System characteristic plotting • Optimization of multi-pump operation     • Impact analysis of system changes   Figure 2: Hydraulic Design for a Pipeline System B) Transient Mode The Transient mode is used for unsteady (transient) analysis of the pipeline system. This mode allows user to analyse incidents such as pump trips and valve closures, and the consequential reaction of surge towers, relief valves and control systems. In this mode, the pipeline system can be designed to withstand these incidents and ensure a safe & reliable operation.  Incidents Protection Phenomenon • Valve closure/opening • Pump trip or start-ups • Surge towers • Air vessels • Pressure relief valves • Air vents • Control systems • Pressure & discharge change • Pressure wave propagation • Water hammer • Wave reflection • Line packing • Cavitation       Figure 3: Analysis of pressure wave propagation through a pipeline C) Control Module/ State The Control module allows user to link a control system to a hydraulic system. This enables us to evaluate the effectiveness of different control philosophies on the hydraulic system and to optimize the control properties. The Control module can be combined with the Liquid, Heat and MST module.   l Liquid Module User can model and analyse a pipeline system for liquid transport. This module contains a wide variety of hydraulic components, including special components such as, surge protection equipment and free surface flow pipes. With this module, user can also access the special system characteristic plotting and pump operation optimization features to improve the performance of their pumping station.   l Heat Module User can model and analyse a pipeline system for heat transport via liquid flow. This module allows us to model district heating networks and process industry piping, for which temperature and heat loss play an important role in the design of a pipeline system.     l MST Module With the Multi-Species Transport (MST) module, user can model and analyse transport of separate batches of fluids through a pipeline system. This module can be used in mining and dredging industry, where multiple fluids are transported in batches.   5.0 SURGE PROTECTION EQUIPMENT   As emphasized in the previous section, a number of techniques can be used for controlling transients in water distribution systems. Some strategies involve design and operational considerations alone, and some also use the addition of dedicated  surge protection devices. The general principles of surge control devices are to store water or otherwise delay the change in flow rate, or to discharge water from line. Devices such as pressure-relief valves, surge anticipation valves, surge vessels, surge tanks, pump-bypass lines, or any combination of these, are commonly used to control maximum pressures. Minimum pressures can be controlled by increasing pump inertia or by adding surge vessels, surge tanks, air-release/vacuum valves, pump-bypass lines, or any combination of that group. The overriding objective is to reduce the rate at which flow changes occur. Specific devices are usually installed at or near the point in which the disturbance is initiated, such as at the pump discharge or by the closing valve ( with the exception of air-relief/ vacuum breaking valves and feed tanks. Figure 4 illustrates typical locations for the various surge protection devices in a water distribution system.       Figure 4: Typical Locations for Various Surge Protection Device   5.1 Surge Control in Water Distribution System   Any surge protection devices and/or operating strategies must be chosen accordingly. The final choice will be based on the initial cause and location of transient disturbances, the system it self, the consequences if remedial action is not taken, and the cost of protection measures. A combination of devices may prove to be the most effective and the most economical. The strategies by which surge control is achieved may be classified as either direct action, or diversionary tactics. Direct actions strategies attempt to influence the behaviour of the primary causes of the flow changes, such as valve or pump operations. Diversionary tactics attempt to control the transient once it has been created,by which fluid is drawn into or expelled from the piping system. 6.0 CONCLUSION   Hydraulic transient, also called pressure surge or water hammer is the means by which a change in a steady state flow and pressure is achieved. When condition in water distribution network are changes, such as by closing a pump or a valve or starting a pump, a series of pressure waves are generated. Problems such as selecting the pipe layout and profile, locating control elements within the system, formulating operating rule, as well as the ongoing the challenges of system management are all influenced by the details of the control system. A detailed transient analysis will offers a comprehensive guide to the selection of surge control and suppression in water distribution system. Using a surge analysis computer model, such as WANDA software by Deltares System, will greatly enhanced engineers ability to better understand and estimate the effects of hydraulic transient, to conceive and evaluate efficient and reliable water supply management as it can be applied in a vast number of industries. WANDA is definitely a favourite program for surge analysis. read more
CSE Advance (SEL) Sdn Bhd added new photo
Nov 30, 2020 at 08:24 am —
Pump Cover

Pump Cover

Specification: 1) Electro galvanized c/wspecial coating material 2) 39cm x 44cm x 58cm in size 3) Suitable for:      GRUNDFOS (CM-PM1/CHM/JPC/JPA)      TSUNAMI (KLM/CMH-K)      LEO (ECH/ECHm-E/ACM/AMS)      TSURUMI  (THS/THS-PC) 4) Reliable 5) Good ventilation 6) 36 Months warranty read more
CSE Advance (SEL) Sdn Bhd added new photo in STOCK CLEARANCE - TDA-F Series Smokespill Axial Fan
Sep 17, 2020 at 02:57 am —
Smokespill Axial Flow Fan

Smokespill Axial Flow Fan

Application Suitable for smoke exhaust system in shopping malls, hospitals, commercial buildings, airport etc. Construction Double flanged casing is produced in mild steel or galvanized steel. Finish Painting or galvanization after manufacture is standard on all parts. Motor Totally enclosed Class H (comply with BS En 12101-3:2002, Class F250, F300, F400) with a min. IP54 protection. Motors up to 2.2kW are usually supplied on DOL starting, motors 3.0kW and above are star/delta starting. Impeller The blades are made of Aluminium. The pitch angle can be adjusted manually. Airflow Direction Air flow from impeller to motor is fitted as standard. Air flow from motor to impeller can be supplied upon request read more
CSE Advance (SEL) Sdn Bhd added new photo in LEO PUMP - Domestic Pump
Sep 17, 2020 at 01:54 am —
MAC 550 Pressure Booster Pump

MAC 550 Pressure Booster Pump

The LEO MAC550 is an intelligent pressure booster system which can automatically adjust performance according to water demand. It provides constant pressure to all taps in a building. Application Water supply and pressure boosting for all domestic applications. Garden watering, building water supply and agriculture. Variable Speed MAC550 can adjust performance automatically by adjusting the motor speed according to water demand. It can provide constant pressure to all taps. Multiple Protection Several protective functions are incorporated to ensure its long service life, including pressure protection, blocking protection, leakage protection, no-water protection, dry-running protection, over-heating protection, over/under-voltage protection. Energy Efficient & Money Saving Permanent magnet frequency-converting motor can automatically adjust the RPM to match the required outlet water which helps reduce power consumption and lower your energy bills. Easy Selection One model for most domestic applications. Low Noise Sound level< 47dB (A) in typical use, thanks to water cooled motor. User Friendly Working pressure and fault codes are displayed on touch control panel, through which you can adjust working pressure. Easy Installation Compact all-in-one solution, integrating high efficiency pump, non­return valve, sensor, speed controller and pressure vessel together.     read more
CSE Advance (SEL) Sdn Bhd added new photo in ALIGNMENT SHIMS
Mar 26, 2020 at 10:47 am —
Shims

Shims

Pre-cut, high quality, stainless steel shims, make alignment of your machines safer and easier. Choose one of our shim cases so that you always have the right shims close to hand. Shims of common size for pumps alignment (75mm) – easy to use Loose shims in packs of 25/50/80 – even special shims Shims marked with thickness – quickly identifiable Small, handy shim cases – easy to transport Burr free shims – safe to handle   read more
next page

Switch to Mobile Version